Review




Structured Review

Biosense Webster variable loop circular catheter vlcc
Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in <t>VLCC.</t> The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.
Variable Loop Circular Catheter Vlcc, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/variable loop circular catheter vlcc/product/Biosense Webster
Average 86 stars, based on 1 article reviews
variable loop circular catheter vlcc - by Bioz Stars, 2026-05
86/100 stars

Images

1) Product Images from "Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter"

Article Title: Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter

Journal: Europace

doi: 10.1093/europace/euag005

Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in VLCC. The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.
Figure Legend Snippet: Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in VLCC. The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.

Techniques Used: Solvent, Magnetic Resonance Imaging



Similar Products

86
Biosense Webster variable loop circular catheter vlcc
Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in <t>VLCC.</t> The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.
Variable Loop Circular Catheter Vlcc, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/variable loop circular catheter vlcc/product/Biosense Webster
Average 86 stars, based on 1 article reviews
variable loop circular catheter vlcc - by Bioz Stars, 2026-05
86/100 stars
  Buy from Supplier

90
Biosense Webster open-irrigated variable-loop circular catheter (vlcc)
Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the <t>VLCC</t> influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.
Open Irrigated Variable Loop Circular Catheter (Vlcc), supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/open-irrigated variable-loop circular catheter (vlcc)/product/Biosense Webster
Average 90 stars, based on 1 article reviews
open-irrigated variable-loop circular catheter (vlcc) - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Biosense Webster variable-loop circular catheter vlcc varipulse
Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the <t>VLCC</t> influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.
Variable Loop Circular Catheter Vlcc Varipulse, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/variable-loop circular catheter vlcc varipulse/product/Biosense Webster
Average 90 stars, based on 1 article reviews
variable-loop circular catheter vlcc varipulse - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Biosense Webster varipulsetm variable-loop circular catheter vlcc
Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the <t>VLCC</t> influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.
Varipulsetm Variable Loop Circular Catheter Vlcc, supplied by Biosense Webster, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/varipulsetm variable-loop circular catheter vlcc/product/Biosense Webster
Average 90 stars, based on 1 article reviews
varipulsetm variable-loop circular catheter vlcc - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in VLCC. The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.

Journal: Europace

Article Title: Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter

doi: 10.1093/europace/euag005

Figure Lengend Snippet: Study design. (A) The current study comprised a series of experiments to evaluate the safety and efficacy of irrigation in VLCC. The corresponding examination was listed in the table. (B) The irrigation effect through 0 to 60 mL/min was presented by infusing a dye-colored solvent under a high-speed camera (1000 fps) in the same moment. ICE, Intracardiac echocardiography; MRI, Magnetic resonance imaging.

Article Snippet: A variable-loop circular catheter (VLCC) with an adjustable irrigation system (VARIPULSE, Biosense Webster, Irvine, CA, USA) and a three-dimensional electro-anatomical system (Carto 3, Biosense Webster, Irvine, CA, USA) was used throughout the experiments.

Techniques: Solvent, Magnetic Resonance Imaging

Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the VLCC influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.

Journal: European Heart Journal. Case Reports

Article Title: Voltage threshold adjustments for a novel pulsed-field ablation catheter with integrated mapping capabilities: lessons from a case series

doi: 10.1093/ehjcr/ytaf231

Figure Lengend Snippet: Comparison of a high-density mapping catheter (Octaray) and a variable-loop circular catheter (Varipulse). The larger electrode size and greater inter-electrode spacing of the VLCC influence signal amplitude and morphology. As a result, voltage threshold adjustments are necessary to achieve a mapping performance comparable to that of a high-density mapping catheter.

Article Snippet: It consists of an open-irrigated variable-loop circular catheter (VLCC) with 10 electrodes (electrode length 3 mm, inter-electrode spacing 7 mm center-to-center) and is capable of both mapping and PFA (Varipulse, Biosense Webster, Irvine, CA, USA).

Techniques: Comparison

The left figure in each panel shows the high-density bipolar voltage map acquired with a dedicated mapping catheter (Octaray) and displayed with the standard voltage thresholds. The right figures show the maps acquired with the novel variable-loop circular catheter (VLCC, Varipulse) displayed with different bipolar voltage thresholds. Patient #1 underwent an index PVI with four isolated veins after PFA. Patient #2 underwent a redo PVI with a reconnected left lower pulmonary vein at the beginning of the procedure. Patient #3 shows wide antral PVI and scar on the posterior wall during a redo case. Patient #4 presented with an anterior scar. This map was acquired during a roof-dependent flutter, the tachycardia mechanism of which was also correctly identified by the VLCC. PFA, pulsed-field ablation; PVI, pulmonary vein isolation.

Journal: European Heart Journal. Case Reports

Article Title: Voltage threshold adjustments for a novel pulsed-field ablation catheter with integrated mapping capabilities: lessons from a case series

doi: 10.1093/ehjcr/ytaf231

Figure Lengend Snippet: The left figure in each panel shows the high-density bipolar voltage map acquired with a dedicated mapping catheter (Octaray) and displayed with the standard voltage thresholds. The right figures show the maps acquired with the novel variable-loop circular catheter (VLCC, Varipulse) displayed with different bipolar voltage thresholds. Patient #1 underwent an index PVI with four isolated veins after PFA. Patient #2 underwent a redo PVI with a reconnected left lower pulmonary vein at the beginning of the procedure. Patient #3 shows wide antral PVI and scar on the posterior wall during a redo case. Patient #4 presented with an anterior scar. This map was acquired during a roof-dependent flutter, the tachycardia mechanism of which was also correctly identified by the VLCC. PFA, pulsed-field ablation; PVI, pulmonary vein isolation.

Article Snippet: It consists of an open-irrigated variable-loop circular catheter (VLCC) with 10 electrodes (electrode length 3 mm, inter-electrode spacing 7 mm center-to-center) and is capable of both mapping and PFA (Varipulse, Biosense Webster, Irvine, CA, USA).

Techniques: Isolation